HOA Y CO LTD, HOA Y; CONG TY TNHH HOA Y;

K16500 Rapid Flash Closed-Cup Tester

K16500 Rapid Flash Closed-Cup Tester

K16500 Rapid Flash Closed-Cup Tester

K16500 Rapid Flash Closed-Cup Tester

K16500 Rapid Flash Closed-Cup Tester
K16500 Rapid Flash Closed-Cup Tester

TRANG CHỦ Sản phẩm Koehler Thiết bị kiểm tra điểm chớp cháy K16500 Rapid Flash Closed-Cup Tester


 

Test Method
Verifies the flash point or the sustained burning qualities of small samples in the range of –30°C to +300°C.

 

Features and Benefits
Conforms to ASTM D3278, D3828, D4206; DOT CFR 49-173.115; IATA;ISO 9038 and related specifications
One minute test with a 2mL sample
Simple to operate

 


 

K16500 Rapid Flash Tester
Rapid Tester® provides rapid determinations of flash point or sustained burning qualities by using a small sample. A flash/no flash test result is achieved in one minute for flash points below 212°F (100°C) with a 2mL sample. Ideally suited for quality assurance and environmental compliance testing as well as actual flashpoint for paints, fragrances, hydrocarbons and other liquids. Open cup models are used for determining sustained burning qualities characteristics of mixtures of flammable and nonflammable liquids or liquids with widely different flash points when assessing flammability characteristics. Features convenient semi-automatic operation for flash/no flash tests. Set the test temperature on the digital display and inject a 2mL or 4mL sample into the sample cup. The tester quickly stabilizes itself at the desired value, permitting the test flame to be applied and the result to be observed by the operator. Unit also performs conventional determinations of actual flash temperature by the small scale closed tester method.

 

Two models are offered: the Closed Cup Model is for routine flash point tests in the range from –30 to +300°C (–22 to +572°F); the Open-Cup Model is for sustained burning tests in the range from ambient to 212°F (100°C). Both models include automatic temperature control with °C/°F selector switch, syringe, electronic timer, integral NIST traceable thermometer, and an external hose adapter valve for connection to a customer-supplied fuel cylinder or other fuel source.

Specifications
Conforms to the specifications of:
ASTM D3278, D3828, D4206; IP 303; ISO 3679, ISO 3680, ISO 9038;
DOT CFR 49-173.115; IATA

Included Accessories
Thermometer, range 32 to 572°F (0 to 300°C)
Syringe

Dimensions lxwxh,in.(cm) 15x23.4x6.3 (38.1x8.6x16.2)
Net Weight: 10 lbs (4.6kg)


 


 

Ordering Information
 
Catalog Number
Product Description
Electrical Requirements
K16500
Rapid Flash Tester, Closed Cup
Aluminum Test Cup/Brass Lid & Shutter

115V

K16591 Rapid Flash Tester, Closed Cup
Aluminum Test Cup/Brass Lid & Shutter

220-240V

K16502 Rapid Flash Tester, Closed Cup
Stainless Steel Test Cup/Lid & Shutter

115V

K16592 Rapid Flash Tester, Closed Cup
Stainless Steel Test Cup/Lid & Shutter

220-240V

K16503 Rapid Flash Tester, Open-Cup
Aluminum Test Cup

115V

K16593 Rapid Flash Tester, Open-Cup
Aluminum Test Cup

220-240V

K16504 Rapid Flash Tester, Open-Cup
Stainless Steel Test Cup

115V

K16594 Rapid Flash Tester, Open-Cup
Stainless Steel Test Cup

220-240V


Accessories
 
Catalog Number
Product Description

Temperature Range

K16506
Fuel Cylinder Valve  
K16507
Heat Transfer Compound for thermometer  
K16508 Metal Cooling Block to facilitate cooling of the sample cup between tests  
K16509 Refrigerant Charged Cooling block to hold cooling mixture for subambient testing  
K16510 Syringe 2mL/4mL  
K16511 Thermometer

32 to 572°F/0 to 300°C

K16512 Thermometer

32 to 230°F

K16513 Thermometer

212 to 572°F

K16514 Thermometer

0 to 110°C

K16515 Thermometer

100 to 300°C

K16516 Thermometer

-36 to +105°F

K16517 Thermometer

-38 to +40°C