HOA Y CO LTD, HOA Y; CONG TY TNHH HOA Y;

CÔNG TY TNHH HOA Ý

HOA Y CO LTD

CÔNG TY HOA Ý

CÔNG TY HOA Ý

CÔNG TY HOA Ý
CÔNG TY HOA Ý

TRANG CHỦ Sản phẩm Orto Alresa Máy ly tâm lạnh Biocen 22R

 

Biocen 22R

 

Biocen 22RThe Biocen 22 R can reach up to 30.034 xg , becoming the necessary tool for most demanding labs. Allows 24 microtubes of 2.2 ml, 32 of 0.2 ml and 8x15 ml, conical.

 

Usually microcentrifuges work with samples sensitive, valuables, or dangerous ( toxic, radioactive, infectious). Ortoalresa has built the Biocen 22 R with several advantages which allow a safe analysis, without interaction of centrifuge, as:

 

  • Cooling system which maintains the sample temperature at 4°C at max speed, 
    regardless of the rotor.
  • Chamber of centrifugation in stainless steel, allowing an easy disinfection on samples 
    leakages, avoiding contamination form the centrifuge.
  • Rotors with hermetic lids.
  • Accessories sterilizables.

 

 

 

 

 


 

 

User friendliness

 

  • LCD screen shown RPM/RCF (on steps 100 RPM/10xg),time, temperature (1°C steps) and braking (1 second steps).
  • Intuitive handling through start, stop, short spin and lid keys.
  • Rotor list on memory.
  • Timer count up/down, from 0 or at “set RPM/RCF” for test reproducibility.
  • Short spin key with speed adjustable.
  • Automatic rotor recognition.
  • Acceleration and braking selectable by operator.
  • 15 memories and pre-cooling program.
  • Automatic open lid.
  • Lid latch lock.
  • Microprocessor controlled.
  • Option: free or locked adjustment of RPM/RCF along the run.

 

 

 


 

 

Features

 

  • Induction motor maintenance free
  • Max. capacity 8 x 15 ml.
  • Speed, up to 30.034 xg/18.100 RPM.
  • Quiet: noise level < 60 dB.

 

 

 


 

 

Safety

 

  • Lid locking and holding.
  • Imbalance switch off.
  • Manual overriding.
  • Chamber of centrifugation in stainless steel.
  • Viewing and calibration port in the lid.
  • Several messages keep the operator informed about the device situation.
  • Guard ring between the chamber of centrifugation and the housing.
  • Lid dropping protection.

 

 

 


 

 

Cooling

 

  • Precooling program with rotor spinning and temperature selectable by operator.
  • 4°C at Max speed as higher.
  • Temperature range from -20°C (-4°F) to 40°C (104°F).
  • Temperature sensor inside the chamber, gas R 404A HFC.

 

 

 


 

 

Standards and EC Directives

 

  • EU Directives: 98/79/EC, 2006/95/EC, 2004/108/EC, 2011/65/EU, 2012/19/EU.
  • Regulation: 1005/2009 & 842/2006.
  • Standards: EN 61010-1, EN 61010-2-020, EN 61326-1.

 

 

 


 

 

accesorios

  RT 222
id
RT 223
id
RT 224
id
RT 252
id
  + info + info + info + info
ROTOR ANGLE FIXED 45º ANGLE FIXED 30º ANGLE FIXED 45º ANGLE FIXED 45º
Max. capacity 24 de 1,5x2 ml. 8 x 15 ml. conical 32 de 0,2 ml. 12 x 5 ml.
RPM 18100 8000 18100 18100
Radius(mm) 82 91 55 87
RCF Max. (xg) 30034 6511 20145 31865
Min.temp. max speed(°C) 0 -2 0 5

 

 


 

 

>> DOWNLOAD BIOCEN 22R CATALOGUE